Update LED Band mit auto Refresch nach Bauteilbewertung

This commit is contained in:
2023-04-28 09:33:09 +02:00
parent 7c921e9e80
commit 7f754ffed0
18 changed files with 81 additions and 85 deletions

View File

@@ -1,5 +1,5 @@
<?xml version="1.0" encoding="utf-8"?>
<?AutomationStudio Version="4.11.3.51 SP" WorkingVersion="4.11"?>
<?AutomationStudio Version="4.11.4.55 SP" WorkingVersion="4.11"?>
<Project Description="Ausgangsprojekt - Entwicklung Elunic" Version="1.00.0" Edition="Standard" EditionComment="Standard" xmlns="http://br-automation.co.at/AS/Project">
<Communication>
<OnlineConfiguration Name="Elunic-Management" DeviceType="TCPIP" DeviceParameters="/IF=tcpip /LOPO=11159 /SA=195" ConnectionParameters="/COMT=5000 /RT=1000 /AM=* /SDT=5 /DAIP=10.13.15.10 /REPO=11159 /ANSL=1" Description="" />

View File

@@ -1,7 +1,7 @@
<?xml version="1.0" encoding="utf-8"?>
<?AutomationStudio Version="4.11.3.51 SP"?>
<?AutomationStudio Version="4.11.4.55 SP"?>
<ProjectSettings xmlns="http://br-automation.co.at/AS/ProjectSettings">
<ConfigurationManager ActiveConfigurationName="CfgL8Neu" />
<ConfigurationManager ActiveConfigurationName="CfgL7b" />
<Deployment Value="ActiveCpu" />
<Print Footer="%cPage: %p" Header="%lProject: %n%c%x" />
</ProjectSettings>

View File

@@ -145,6 +145,7 @@ PROGRAM _CYCLIC
END_CASE
//Band weiterlaufen lassen
IF gLEDState.bNextPos OR (VCTestMode.bCommand AND EDGEPOS (gBlinker.bBlink0_1)) THEN
gLEDState.usWritePos := (gLEDState.usWritePos -1);
IF gLEDState.usWritePos > MAX_CONV_POS THEN
@@ -168,6 +169,13 @@ PROGRAM _CYCLIC
bLEDCmd := TRUE;
END_IF
//Band LED auffrischen
IF gLEDState.bReFresh AND NOT bLEDCmd THEN
gLEDState.bReFresh := FALSE;
bLEDCmd := TRUE;
END_IF
//Call FUBs
FUBs.FrameWrite1 ();

View File

@@ -39,7 +39,8 @@ TYPE
END_STRUCT;
gtyp_LEDState : STRUCT (*LED Status Band*)
bNextPos : BOOL; (*Trigger n<>chste Position*)
bLEDOut : BOOL; (*Trigger n<>chste Position*)
bReFresh : BOOL; (*LEDs Aktualisieren*)
bLEDOut : BOOL; (*LED Ausschalten*)
usWritePos : USINT;
usSegState : ARRAY[1..MAX_CONV_POS]OF USINT; (*Segmentstatus Segmentl<74>nge 100mm*)
END_STRUCT;

View File

@@ -62,7 +62,7 @@ ACTION DoCheckParameter:
END_ACTION
//Neue Position (Takt) erkennen / berechnen
//Neue Position (Takt) erkennen / berechnen
ACTION DoGetNewPosition:
IF (Parameter.uiLineID = LINE_VAL_SPS_L1a) OR (Parameter.uiLineID = LINE_VAL_SPS_L1b) THEN
//Bandposition kommt ueber Bus
@@ -336,7 +336,7 @@ ACTION DoLinectrlInterface:
usOuLineCtrlRaw[10] := UDINT_TO_USINT (SHR (udTemp, 8));
END_IF
//Part ID String / Serial zur<EFBFBD>ckspiegeln
//Part ID String / Serial zurueckspiegeln
//-----------------------------------------------
IF (Parameter.uiLineID = LINE_VAL_SPS_L1a) THEN
//Variante SPS Linie 1a

View File

@@ -454,6 +454,7 @@ PROGRAM _CYCLIC
gLEDState.usSegState[usTemp] := usSegState;
END_IF
END_FOR
gLEDState.bReFresh := TRUE;
Status.usLatchPartIndexResult := LineInspectorInterface.FromLineInspector.usPartindexResult;
END_IF

View File

@@ -1,37 +1,37 @@
<?xml version="1.0" encoding="utf-8"?>
<?AutomationStudio Version=4.9.4.92 FileVersion="4.9"?>
<?AutomationStudio Version=4.11.4.55 FileVersion="4.9"?>
<Hardware xmlns="http://br-automation.co.at/AS/Hardware">
<Module Name="X20BM11" Type="X20BM11" Version="1.0.0.1">
<Module Name="X20BM11" Type="X20BM11" Version="1.1.0.0">
<Connection Connector="X2X1" TargetModule="X20CP3484_1" TargetConnector="IF6" />
</Module>
<Module Name="X20BM11a" Type="X20BM11" Version="1.0.0.1">
<Module Name="X20BM11a" Type="X20BM11" Version="1.1.0.0">
<Connection Connector="X2X1" TargetModule="X20BM11i" TargetConnector="X2X2" />
</Module>
<Module Name="X20BM11b" Type="X20BM11" Version="1.0.0.1">
<Module Name="X20BM11b" Type="X20BM11" Version="1.1.0.0">
<Connection Connector="X2X1" TargetModule="X20BM11j" TargetConnector="X2X2" />
</Module>
<Module Name="X20BM11c" Type="X20BM11" Version="1.0.0.1">
<Module Name="X20BM11c" Type="X20BM11" Version="1.1.0.0">
<Connection Connector="X2X1" TargetModule="X20BM11" TargetConnector="X2X2" />
</Module>
<Module Name="X20BM11d" Type="X20BM11" Version="1.0.0.1">
<Module Name="X20BM11d" Type="X20BM11" Version="1.1.0.0">
<Connection Connector="X2X1" TargetModule="X20BM11c" TargetConnector="X2X2" />
</Module>
<Module Name="X20BM11e" Type="X20BM11" Version="1.0.0.1">
<Module Name="X20BM11e" Type="X20BM11" Version="1.1.0.0">
<Connection Connector="X2X1" TargetModule="X20BM11d" TargetConnector="X2X2" />
</Module>
<Module Name="X20BM11f" Type="X20BM11" Version="1.0.0.1">
<Module Name="X20BM11f" Type="X20BM11" Version="1.1.0.0">
<Connection Connector="X2X1" TargetModule="X20BM11e" TargetConnector="X2X2" />
</Module>
<Module Name="X20BM11g" Type="X20BM11" Version="1.0.0.1">
<Module Name="X20BM11g" Type="X20BM11" Version="1.1.0.0">
<Connection Connector="X2X1" TargetModule="X20BM11a" TargetConnector="X2X2" />
</Module>
<Module Name="X20BM11h" Type="X20BM11" Version="1.0.0.1">
<Module Name="X20BM11h" Type="X20BM11" Version="1.1.0.0">
<Connection Connector="X2X1" TargetModule="X20BM11g" TargetConnector="X2X2" />
</Module>
<Module Name="X20BM11i" Type="X20BM11" Version="1.0.0.1">
<Module Name="X20BM11i" Type="X20BM11" Version="1.1.0.0">
<Connection Connector="X2X1" TargetModule="X20BM11f" TargetConnector="X2X2" />
</Module>
<Module Name="X20BM11j" Type="X20BM11" Version="1.0.0.1">
<Module Name="X20BM11j" Type="X20BM11" Version="1.1.0.0">
<Connection Connector="X2X1" TargetModule="X20BM11h" TargetConnector="X2X2" />
</Module>
<Module Name="X20CP3484_1" Type="X20CP3484-1" Version="1.1.5.0">

View File

@@ -27,7 +27,7 @@
<Io Supervision="False" />
<Opc WindowsServer="False" />
<Transfer DownloadMode="Copy" PromptBeforeProject="True" SavedOfflineInstallationFolder="" SavedPipDestinationFolder="" SavedRuntimeUtilityCenterPackagePath="" TransferOnlyRelevantChanges="True" />
<Vc FirmwareVersion="V4.72.6" />
<Vc FirmwareVersion="V4.72.7" />
<OnlineConfiguration Name="Elunic-Management" DeviceType="TCPIP" DeviceParameters="/IF=tcpip /LOPO=11159 /SA=194" ConnectionParameters="/COMT=5000 /RT=1000 /AM=* /SDT=5 /DAIP=10.13.15.10 /REPO=11159 /ANSL=1" Description="" />
</Configuration>
</Cpu>

View File

@@ -1,37 +1,37 @@
<?xml version="1.0" encoding="utf-8"?>
<?AutomationStudio Version=4.9.4.92 FileVersion="4.9"?>
<?AutomationStudio Version=4.11.4.55 FileVersion="4.9"?>
<Hardware xmlns="http://br-automation.co.at/AS/Hardware">
<Module Name="X20BM11" Type="X20BM11" Version="1.0.0.1">
<Module Name="X20BM11" Type="X20BM11" Version="1.1.0.0">
<Connection Connector="X2X1" TargetModule="X20CP3484_1" TargetConnector="IF6" />
</Module>
<Module Name="X20BM11a" Type="X20BM11" Version="1.0.0.1">
<Module Name="X20BM11a" Type="X20BM11" Version="1.1.0.0">
<Connection Connector="X2X1" TargetModule="X20BM11i" TargetConnector="X2X2" />
</Module>
<Module Name="X20BM11b" Type="X20BM11" Version="1.0.0.1">
<Module Name="X20BM11b" Type="X20BM11" Version="1.1.0.0">
<Connection Connector="X2X1" TargetModule="X20BM11j" TargetConnector="X2X2" />
</Module>
<Module Name="X20BM11c" Type="X20BM11" Version="1.0.0.1">
<Module Name="X20BM11c" Type="X20BM11" Version="1.1.0.0">
<Connection Connector="X2X1" TargetModule="X20BM11" TargetConnector="X2X2" />
</Module>
<Module Name="X20BM11d" Type="X20BM11" Version="1.0.0.1">
<Module Name="X20BM11d" Type="X20BM11" Version="1.1.0.0">
<Connection Connector="X2X1" TargetModule="X20BM11c" TargetConnector="X2X2" />
</Module>
<Module Name="X20BM11e" Type="X20BM11" Version="1.0.0.1">
<Module Name="X20BM11e" Type="X20BM11" Version="1.1.0.0">
<Connection Connector="X2X1" TargetModule="X20BM11d" TargetConnector="X2X2" />
</Module>
<Module Name="X20BM11f" Type="X20BM11" Version="1.0.0.1">
<Module Name="X20BM11f" Type="X20BM11" Version="1.1.0.0">
<Connection Connector="X2X1" TargetModule="X20BM11e" TargetConnector="X2X2" />
</Module>
<Module Name="X20BM11g" Type="X20BM11" Version="1.0.0.1">
<Module Name="X20BM11g" Type="X20BM11" Version="1.1.0.0">
<Connection Connector="X2X1" TargetModule="X20BM11a" TargetConnector="X2X2" />
</Module>
<Module Name="X20BM11h" Type="X20BM11" Version="1.0.0.1">
<Module Name="X20BM11h" Type="X20BM11" Version="1.1.0.0">
<Connection Connector="X2X1" TargetModule="X20BM11g" TargetConnector="X2X2" />
</Module>
<Module Name="X20BM11i" Type="X20BM11" Version="1.0.0.1">
<Module Name="X20BM11i" Type="X20BM11" Version="1.1.0.0">
<Connection Connector="X2X1" TargetModule="X20BM11f" TargetConnector="X2X2" />
</Module>
<Module Name="X20BM11j" Type="X20BM11" Version="1.0.0.1">
<Module Name="X20BM11j" Type="X20BM11" Version="1.1.0.0">
<Connection Connector="X2X1" TargetModule="X20BM11h" TargetConnector="X2X2" />
</Module>
<Module Name="X20CP3484_1" Type="X20CP3484-1" Version="1.1.5.0">

View File

@@ -27,7 +27,7 @@
<Io Supervision="False" />
<Opc WindowsServer="False" />
<Transfer DownloadMode="Copy" PromptBeforeProject="True" SavedOfflineInstallationFolder="" SavedPipDestinationFolder="" SavedRuntimeUtilityCenterPackagePath="" TransferOnlyRelevantChanges="True" />
<Vc FirmwareVersion="V4.72.6" />
<Vc FirmwareVersion="V4.72.7" />
<OnlineConfiguration Name="Elunic-Management" DeviceType="TCPIP" DeviceParameters="/IF=tcpip /LOPO=11159 /SA=194" ConnectionParameters="/COMT=5000 /RT=1000 /AM=* /SDT=5 /DAIP=10.13.15.10 /REPO=11159 /ANSL=1" Description="" />
</Configuration>
</Cpu>

View File

@@ -1,37 +1,37 @@
<?xml version="1.0" encoding="utf-8"?>
<?AutomationStudio Version=4.9.4.92 FileVersion="4.9"?>
<?AutomationStudio Version=4.11.4.55 FileVersion="4.9"?>
<Hardware xmlns="http://br-automation.co.at/AS/Hardware">
<Module Name="X20BM11" Type="X20BM11" Version="1.0.0.1">
<Module Name="X20BM11" Type="X20BM11" Version="1.1.0.0">
<Connection Connector="X2X1" TargetModule="X20CP3484_1" TargetConnector="IF6" />
</Module>
<Module Name="X20BM11a" Type="X20BM11" Version="1.0.0.1">
<Module Name="X20BM11a" Type="X20BM11" Version="1.1.0.0">
<Connection Connector="X2X1" TargetModule="X20BM11f" TargetConnector="X2X2" />
</Module>
<Module Name="X20BM11b" Type="X20BM11" Version="1.0.0.1" Disabled="true">
<Module Name="X20BM11b" Type="X20BM11" Version="1.1.0.0" Disabled="true">
<Connection Connector="X2X1" TargetModule="X20BM11j" TargetConnector="X2X2" />
</Module>
<Module Name="X20BM11c" Type="X20BM11" Version="1.0.0.1">
<Module Name="X20BM11c" Type="X20BM11" Version="1.1.0.0">
<Connection Connector="X2X1" TargetModule="X20BM11" TargetConnector="X2X2" />
</Module>
<Module Name="X20BM11d" Type="X20BM11" Version="1.0.0.1">
<Module Name="X20BM11d" Type="X20BM11" Version="1.1.0.0">
<Connection Connector="X2X1" TargetModule="X20BM11c" TargetConnector="X2X2" />
</Module>
<Module Name="X20BM11e" Type="X20BM11" Version="1.0.0.1">
<Module Name="X20BM11e" Type="X20BM11" Version="1.1.0.0">
<Connection Connector="X2X1" TargetModule="X20BM11d" TargetConnector="X2X2" />
</Module>
<Module Name="X20BM11f" Type="X20BM11" Version="1.0.0.1">
<Module Name="X20BM11f" Type="X20BM11" Version="1.1.0.0">
<Connection Connector="X2X1" TargetModule="X20BM11e" TargetConnector="X2X2" />
</Module>
<Module Name="X20BM11g" Type="X20BM11" Version="1.0.0.1">
<Module Name="X20BM11g" Type="X20BM11" Version="1.1.0.0">
<Connection Connector="X2X1" TargetModule="X20BM11a" TargetConnector="X2X2" />
</Module>
<Module Name="X20BM11h" Type="X20BM11" Version="1.0.0.1">
<Module Name="X20BM11h" Type="X20BM11" Version="1.1.0.0">
<Connection Connector="X2X1" TargetModule="X20BM11g" TargetConnector="X2X2" />
</Module>
<Module Name="X20BM11i" Type="X20BM11" Version="1.0.0.1" Disabled="true">
<Module Name="X20BM11i" Type="X20BM11" Version="1.1.0.0" Disabled="true">
<Connection Connector="X2X1" TargetModule="X20BM11b" TargetConnector="X2X2" />
</Module>
<Module Name="X20BM11j" Type="X20BM11" Version="1.0.0.1">
<Module Name="X20BM11j" Type="X20BM11" Version="1.1.0.0">
<Connection Connector="X2X1" TargetModule="X20BM11h" TargetConnector="X2X2" />
</Module>
<Module Name="X20CP3484_1" Type="X20CP3484-1" Version="1.1.5.0">

View File

@@ -28,7 +28,7 @@
<Io Supervision="False" />
<Opc WindowsServer="False" />
<Transfer DownloadMode="Copy" PromptBeforeProject="True" SavedOfflineInstallationFolder="" SavedPipDestinationFolder="" SavedRuntimeUtilityCenterPackagePath="" TransferOnlyRelevantChanges="True" />
<Vc FirmwareVersion="V4.72.6" />
<Vc FirmwareVersion="V4.72.7" />
<OnlineConfiguration Name="Elunic-Management" DeviceType="TCPIP" DeviceParameters="/IF=tcpip /LOPO=11159 /SA=195" ConnectionParameters="/COMT=5000 /RT=1000 /AM=* /SDT=5 /DAIP=10.13.15.10 /REPO=11159 /ANSL=1" Description="" />
</Configuration>
</Cpu>

View File

@@ -28,7 +28,7 @@
<Io Supervision="False" />
<Opc WindowsServer="False" />
<Transfer DownloadMode="Copy" PromptBeforeProject="True" SavedOfflineInstallationFolder="" SavedPipDestinationFolder="" SavedRuntimeUtilityCenterPackagePath="" TransferOnlyRelevantChanges="True" />
<Vc FirmwareVersion="V4.72.6" />
<Vc FirmwareVersion="V4.72.7" />
<OnlineConfiguration Name="Elunic-Management" DeviceType="TCPIP" DeviceParameters="/IF=tcpip /LOPO=11159 /SA=195" ConnectionParameters="/COMT=5000 /RT=1000 /AM=* /SDT=5 /DAIP=10.13.15.10 /REPO=11159 /ANSL=1" Description="" />
</Configuration>
</Cpu>

View File

@@ -1,22 +1,22 @@
<?xml version="1.0" encoding="utf-8"?>
<?AutomationStudio Version=4.9.4.92 FileVersion="4.9"?>
<?AutomationStudio Version=4.11.4.55 FileVersion="4.9"?>
<Hardware xmlns="http://br-automation.co.at/AS/Hardware">
<Module Name="X20BM11a" Type="X20BM11" Version="1.0.0.1">
<Module Name="X20BM11a" Type="X20BM11" Version="1.1.0.0">
<Connection Connector="X2X1" TargetModule="X20BM11e" TargetConnector="X2X2" />
</Module>
<Module Name="X20BM11b" Type="X20BM11" Version="1.1.0.0">
<Connection Connector="X2X1" TargetModule="X20CP3484_1" TargetConnector="IF6" />
</Module>
<Module Name="X20BM11c" Type="X20BM11" Version="1.0.0.1">
<Module Name="X20BM11c" Type="X20BM11" Version="1.1.0.0">
<Connection Connector="X2X1" TargetModule="X20BM11b" TargetConnector="X2X2" />
</Module>
<Module Name="X20BM11d" Type="X20BM11" Version="1.0.0.1">
<Module Name="X20BM11d" Type="X20BM11" Version="1.1.0.0">
<Connection Connector="X2X1" TargetModule="X20BM11c" TargetConnector="X2X2" />
</Module>
<Module Name="X20BM11e" Type="X20BM11" Version="1.0.0.1">
<Module Name="X20BM11e" Type="X20BM11" Version="1.1.0.0">
<Connection Connector="X2X1" TargetModule="X20BM11d" TargetConnector="X2X2" />
</Module>
<Module Name="X20BM11g" Type="X20BM11" Version="1.0.0.1">
<Module Name="X20BM11g" Type="X20BM11" Version="1.1.0.0">
<Connection Connector="X2X1" TargetModule="X20BM11a" TargetConnector="X2X2" />
</Module>
<Module Name="X20CP3484_1" Type="X20CP3484-1" Version="1.1.5.0">

View File

@@ -2,14 +2,15 @@
<?AutomationStudio FileVersion="4.9"?>
<BR.AS.HardwareTopology>
<TimeStamps>
<TimeStamp LogicalPath="CfgL8.Hardware.hw" LastWriteTime="11/19/2021 15:21:23" />
<TimeStamp LogicalPath="CfgSPSL1a.Hardware.hw" LastWriteTime="12/21/2022 11:17:42" />
</TimeStamps>
<Modules>
<Module Name="X20CP3484_1" Type="X20CP3484-1" X="100" Y="100" />
<Module Name="X20IF1063_1" Type="X20IF1063-1" X="212" Y="100" />
<Module Name="X20BM11" Type="X20BM11" X="300" Y="100" />
<Module Name="X20IF10G3_1" Type="X20IF10G3-1" X="237" Y="100" />
<Module Name="X20IF10E3_1" Type="X20IF10E3-1" X="212" Y="100" />
<Module Name="X20BM11b" Type="X20BM11" X="300" Y="100" />
<Module Name="X20CS1030" Type="X20CS1030" X="300" Y="100" />
<Module Name="X20TB12a" Type="X20TB12" X="300" Y="127" />
<Module Name="X20TB12c" Type="X20TB12" X="300" Y="127" />
<Module Name="X20BM11c" Type="X20BM11" X="313" Y="100" />
<Module Name="X20DI9371-17K1" Type="X20DI9371" X="313" Y="100" />
<Module Name="X20TB12b" Type="X20TB12" X="313" Y="127" />
@@ -19,27 +20,12 @@
<Module Name="X20BM11e" Type="X20BM11" X="339" Y="100" />
<Module Name="X20DI9371-18K1" Type="X20DI9371" X="339" Y="100" />
<Module Name="X20TB12e" Type="X20TB12" X="339" Y="127" />
<Module Name="X20BM11f" Type="X20BM11" X="352" Y="100" />
<Module Name="X20DI9371-18K2" Type="X20DI9371" X="352" Y="100" />
<Module Name="X20TB12f" Type="X20TB12" X="352" Y="127" />
<Module Name="X20BM11a" Type="X20BM11" X="365" Y="100" />
<Module Name="X20DO9322-19K1" Type="X20DO9322" X="365" Y="100" />
<Module Name="X20TB12" Type="X20TB12" X="365" Y="127" />
<Module Name="X20BM11g" Type="X20BM11" X="378" Y="100" />
<Module Name="X20DO9322-19K2" Type="X20DO9322" X="378" Y="100" />
<Module Name="X20TB12g" Type="X20TB12" X="378" Y="127" />
<Module Name="X20BM11h" Type="X20BM11" X="391" Y="100" />
<Module Name="X20DO9322-19K3" Type="X20DO9322" X="391" Y="100" />
<Module Name="X20TB12h" Type="X20TB12" X="391" Y="127" />
<Module Name="X20BM11j" Type="X20BM11" X="404" Y="100" />
<Module Name="X20DC1196" Type="X20DC1196" X="404" Y="100" />
<Module Name="X20TB12j" Type="X20TB12" X="404" Y="127" />
<Module Name="X20BM11b" Type="X20BM11" X="417" Y="100" />
<Module Name="X20DC1176" Type="X20DC1176" X="417" Y="100" />
<Module Name="X20TB12c" Type="X20TB12" X="417" Y="127" />
<Module Name="X20BM11i" Type="X20BM11" X="430" Y="100" />
<Module Name="X20DC1178" Type="X20DC1178" X="430" Y="100" />
<Module Name="X20TB12i" Type="X20TB12" X="430" Y="127" />
<Module Name="X20BM11a" Type="X20BM11" X="352" Y="100" />
<Module Name="X20DO9322-19K1" Type="X20DO9322" X="352" Y="100" />
<Module Name="X20TB12" Type="X20TB12" X="352" Y="127" />
<Module Name="X20BM11g" Type="X20BM11" X="365" Y="100" />
<Module Name="X20DO9322-19K2" Type="X20DO9322" X="365" Y="100" />
<Module Name="X20TB12g" Type="X20TB12" X="365" Y="127" />
</Modules>
<Links />
<InfoElements />

Binary file not shown.

Before

Width:  |  Height:  |  Size: 271 KiB

After

Width:  |  Height:  |  Size: 250 KiB

View File

@@ -1,22 +1,22 @@
<?xml version="1.0" encoding="utf-8"?>
<?AutomationStudio Version=4.9.4.92 FileVersion="4.9"?>
<?AutomationStudio Version=4.11.4.55 FileVersion="4.9"?>
<Hardware xmlns="http://br-automation.co.at/AS/Hardware">
<Module Name="X20BM11a" Type="X20BM11" Version="1.0.0.1">
<Module Name="X20BM11a" Type="X20BM11" Version="1.1.0.0">
<Connection Connector="X2X1" TargetModule="X20BM11e" TargetConnector="X2X2" />
</Module>
<Module Name="X20BM11b" Type="X20BM11" Version="1.1.0.0">
<Connection Connector="X2X1" TargetModule="X20CP3484_1" TargetConnector="IF6" />
</Module>
<Module Name="X20BM11c" Type="X20BM11" Version="1.0.0.1">
<Module Name="X20BM11c" Type="X20BM11" Version="1.1.0.0">
<Connection Connector="X2X1" TargetModule="X20BM11b" TargetConnector="X2X2" />
</Module>
<Module Name="X20BM11d" Type="X20BM11" Version="1.0.0.1">
<Module Name="X20BM11d" Type="X20BM11" Version="1.1.0.0">
<Connection Connector="X2X1" TargetModule="X20BM11c" TargetConnector="X2X2" />
</Module>
<Module Name="X20BM11e" Type="X20BM11" Version="1.0.0.1">
<Module Name="X20BM11e" Type="X20BM11" Version="1.1.0.0">
<Connection Connector="X2X1" TargetModule="X20BM11d" TargetConnector="X2X2" />
</Module>
<Module Name="X20BM11g" Type="X20BM11" Version="1.0.0.1">
<Module Name="X20BM11g" Type="X20BM11" Version="1.1.0.0">
<Connection Connector="X2X1" TargetModule="X20BM11a" TargetConnector="X2X2" />
</Module>
<Module Name="X20CP3484_1" Type="X20CP3484-1" Version="1.1.5.0">

View File

@@ -1,7 +1,7 @@
<?xml version="1.0" encoding="utf-8"?>
<?AutomationStudio Version="4.11.3.51 SP"?>
<?AutomationStudio Version="4.11.4.55 SP"?>
<ProjectSettings xmlns="http://br-automation.co.at/AS/ProjectSettings">
<ConfigurationManager ActiveConfigurationName="CfgL8Neu" />
<ConfigurationManager ActiveConfigurationName="CfgL7b" />
<Deployment Value="ActiveCpu" />
<Print Footer="%cPage: %p" Header="%lProject: %n%c%x" />
</ProjectSettings>