- Removed Acopos CPU configuration (also Libs)

- Added DI Module to X20 Cpu (fixed sysconf.br)
- Upgraded X20 CPU Runtime (removed old version)
- Added Input to m_OG and removed Stairhous functionality
This commit is contained in:
Michael Rest
2010-08-08 12:58:51 +02:00
parent e0fa261c9a
commit a77eacb9bc
124 changed files with 10380 additions and 21129 deletions

View File

@@ -7,6 +7,7 @@ VAR
A6 : DO12Module;
A7 : DI12Module;
A9 : Temp4Module;
A10 : DI12Module;
iAITempAussen : INT; (*Aussentemperatur*)
iAITempMWZ : INT; (*Michi Wohnzimmertemperatur*)
iAITempMBad : INT; (*Michi Badtemperatur*)

View File

@@ -2,7 +2,7 @@ PROGRAM _CYCLIC
(* cyclic program *)
;Mapping DI on local VAR
INKeyOnOff ;Toggle On / Off
INKeyOnOff = A10.DIn[0] ;Toggle On / Off
INKeyOn = False
INKeyOff = False

View File

@@ -1,7 +1,7 @@
PROGRAM _INIT
(* init program *)
xms = 100 ; 100ms Task
lStairFunction = True
lStairFunction = False
iStairFunction = 7200 ; sec
END_PROGRAM

View File

@@ -1,8 +0,0 @@
<?xml version="1.0" encoding="utf-8"?>
<?AutomationStudio Version=3.0.71.31 SP05?>
<Configuration xmlns="http://br-automation.co.at/AS/Configuration">
<Objects>
<Object Type="File" Description="Hardware topology">Hardware.hc</Object>
<Object Type="PLC" Description="Files belonging to this PLC">PLC1</Object>
</Objects>
</Configuration>

Binary file not shown.

View File

@@ -1,26 +0,0 @@
<?xml version="1.0" encoding="utf-8"?>
<?AutomationStudio Version=3.0.71.31 SP05?>
<NcConfiguration Version="2.16.1" NcSwId="acp10">
<Group ID="ACP10CF1_typ" Description="">
<Parameter ID="cnt_nettrc_rec_drive" Value="750" />
<Parameter ID="bufsize_trace_upload" Value="1200" />
<Parameter ID="tc_nc_man_task" Value="Cyclic #1" />
<Parameter ID="glob_pv_as_ncobject" Value="Yes" />
<Group ID="network_init">
<Parameter ID="ncsw_init_execute" Value="Yes" />
<Parameter ID="automatic_execute" Value="No" />
<Parameter ID="node_nr_warning" Value="Yes" />
<Parameter ID="net_err_before_ncact" Value="Yes" />
</Group>
<Group ID="nettrc">
<Parameter ID="enter_parsecrec" Value="Yes" />
<Parameter ID="enter_ncaction" Value="Yes" />
<Parameter ID="save_ring_startidx" Value="No" />
</Group>
<Group ID="can_if[0]">
<Parameter ID="if_name" Value="IF2" />
<Parameter ID="hprio_cobs_appl" Value="0" />
<Parameter ID="hprio_uswrcob" Value="0" />
</Group>
</Group>
</NcConfiguration>

View File

@@ -1,6 +0,0 @@
<?xml version="1.0" encoding="utf-8"?>
<?AutomationStudio Version=3.0.71.31 SP05?>
<NcMapping NcSwId="acp10">
<NcObject Name="gAxisScr1" ModuleAddress="IF2.ST1" InterfaceType="CAN" Type="ncAXIS" Channel="1" InitParameter="ScrAxis" AcoposParameter="ScrAcoTab" Disabled="FALSE" ModuleDisabled="FALSE" />
<NcObject Name="IF2.ST1.VAxis1" ModuleAddress="IF2.ST1" InterfaceType="CAN" Type="ncV_AXIS" Channel="1" Disabled="TRUE" ModuleDisabled="FALSE" />
</NcMapping>

View File

@@ -1,285 +0,0 @@
<?xml version="1.0" encoding="utf-8"?>
<?AutomationStudio Version=?>
<RuntimeConfiguration Version="3.1.1">
<Module ID="$root" Hardware="8AC141.60-2">
<Group ID="IO">
<Selector ID="FunctionModel" Value="Standard">
<Group ID="General">
<Parameter ID="Supervision" Value="on" />
<Group ID="Counter">
<Parameter ID="CounterMode" Value="no counter" />
<Parameter ID="CountFrequency" Value="4MHz" />
<Parameter ID="StartMeasurement" Value="positive edge" />
</Group>
</Group>
<Group ID="ChannelConfiguration">
<Parameter ID="Direction01" Value="input" />
<Parameter ID="Direction02" Value="input" />
<Parameter ID="Direction03" Value="input" />
</Group>
</Selector>
</Group>
<Group ID="Ethernet">
<Parameter ID="EthernetHostName" Value="BR_HOST" />
<Parameter ID="EthernetDefaultGateway" />
<Group ID="Routes" />
</Group>
<Group ID="DNS">
<Selector ID="ActivateDns" Value="0" />
</Group>
<Group ID="AdditionalHardware" />
<Group ID="OPC">
<Parameter ID="ActivateOpc" Value="0" />
<Parameter ID="OpcTagsPassword" />
</Group>
<Group ID="WebServer">
<Selector ID="ActivateWebServer" Value="0" />
</Group>
<Group ID="SystemDiagnostics">
<Selector ID="ActivateSdm" Value="0" />
</Group>
</Module>
<Module ID="IF1" Hardware="8AC141.60-2 (Ser)">
<Group ID="Device">
<Parameter ID="Baudrate" Value="57600" />
<Parameter ID="ReceiveIdleTime" Value="5" />
<Parameter ID="Parity" Value="E" />
<Parameter ID="DataBits" Value="8" />
<Parameter ID="StopBits" Value="1" />
</Group>
<Group ID="INAModem">
<Selector ID="ActivateModem" Value="0" />
</Group>
<Group ID="Network">
<Selector ID="NetworkProtocol" Value="Disable">
<Group ID="INA">
<Parameter ID="ActivateIna" Value="1" />
</Group>
</Selector>
</Group>
</Module>
<Module ID="IF2" Hardware="8AC141.60-2 (Canio)">
<Group ID="Device">
<Selector ID="BaudrateSelection" Value="0">
<Parameter ID="Baudrate" Value="500000" />
</Selector>
<Parameter ID="IdentifierLength" Value="0" />
<Group ID="Advanced">
<Parameter ID="HighWatermark" Value="1" />
<Parameter ID="ReceiveTimeout" Value="10" />
</Group>
</Group>
<Group ID="INA">
<Selector ID="Arnc0Excl" Value="0">
<Parameter ID="ActivateIna" Value="0" />
<Parameter ID="InaNodeCount" Value="32" />
<Parameter ID="InaBaseID" Value="1598" />
</Selector>
</Group>
<Group ID="CANIO">
<Parameter ID="ActivateCANIO" Value="1" />
<Parameter ID="Timeout" Value="1000" />
<Parameter ID="Retries" Value="3" />
<Parameter ID="Mode" Value="CANIO" />
</Group>
<Group ID="CANopen">
<Selector ID="ActivateCanOpen" Value="0" />
</Group>
</Module>
<Module ID="IF3" Hardware="8AC141.60-2 (Canio)">
<Group ID="Device">
<Selector ID="BaudrateSelection" Value="0">
<Parameter ID="Baudrate" Value="500000" />
</Selector>
<Parameter ID="IdentifierLength" Value="0" />
<Group ID="Advanced">
<Parameter ID="HighWatermark" Value="1" />
<Parameter ID="ReceiveTimeout" Value="10" />
</Group>
</Group>
<Group ID="INA">
<Selector ID="Arnc0Excl" Value="0">
<Parameter ID="ActivateIna" Value="0" />
<Parameter ID="InaNodeCount" Value="32" />
<Parameter ID="InaBaseID" Value="1598" />
</Selector>
</Group>
<Group ID="CANIO">
<Parameter ID="ActivateCANIO" Value="1" />
<Parameter ID="Timeout" Value="1000" />
<Parameter ID="Retries" Value="3" />
<Parameter ID="Mode" Value="CANIO" />
</Group>
<Group ID="CANopen">
<Selector ID="ActivateCanOpen" Value="0" />
</Group>
</Module>
<Module ID="IF4" Hardware="8AC141.60-2 (X2x)">
<Group ID="X2X">
<Parameter ID="ActivateX2X" Value="1" />
<Parameter ID="CycleTime" Value="4000" />
<Parameter ID="BusLength" Value="1000" />
<Group ID="Advanced">
<Parameter ID="Stations" Value="64" />
<Parameter ID="AsyncPayload" Value="80" />
<Parameter ID="Asymmetric" Value="off" />
</Group>
</Group>
</Module>
<Module ID="IF6" Hardware="8AC141.60-2 (Eth)">
<Selector ID="ActivateDevice" Value="1">
<Group ID="Device">
<Parameter ID="Baudrate" Value="0" />
<Selector ID="Mode" Value="Manual">
<Parameter ID="InternetAddress" Value="192.168.11.239" />
<Parameter ID="SubnetMask" Value="255.255.255.0" />
</Selector>
</Group>
<Group ID="INA">
<Parameter ID="ActivateIna" Value="1" />
<Parameter ID="InaPort" Value="11159" />
</Group>
<Group ID="SNMP" />
<Group ID="Modbus">
<Selector ID="ActivateModbus" Value="0" />
</Group>
</Selector>
</Module>
<Module ID="IF4.ST1" Hardware="X20DI9371">
<Selector ID="FunctionModel" Value="Standard">
<Group ID="General">
<Parameter ID="Supervision" Value="off" />
<Parameter ID="ModuleInfo" Value="off" />
<Parameter ID="InputFilter" Value="10" />
</Group>
<Group ID="Simulation">
<Parameter ID="SimSlave" />
</Group>
</Selector>
</Module>
<Module ID="IF4.ST2" Hardware="X20DI9371">
<Selector ID="FunctionModel" Value="Standard">
<Group ID="General">
<Parameter ID="Supervision" Value="off" />
<Parameter ID="ModuleInfo" Value="off" />
<Parameter ID="InputFilter" Value="10" />
</Group>
<Group ID="Simulation">
<Parameter ID="SimSlave" />
</Group>
</Selector>
</Module>
<Module ID="IF4.ST3" Hardware="X20DI9371">
<Selector ID="FunctionModel" Value="Standard">
<Group ID="General">
<Parameter ID="Supervision" Value="off" />
<Parameter ID="ModuleInfo" Value="off" />
<Parameter ID="InputFilter" Value="10" />
</Group>
<Group ID="Simulation">
<Parameter ID="SimSlave" />
</Group>
</Selector>
</Module>
<Module ID="IF4.ST4" Hardware="X20DO9322">
<Selector ID="FunctionModel" Value="Standard">
<Group ID="General">
<Parameter ID="Supervision" Value="off" />
<Parameter ID="ModuleInfo" Value="off" />
<Parameter ID="StatusInfo" Value="on" />
<Parameter ID="DigitalOutputsPacked" Value="off" />
</Group>
<Group ID="Simulation">
<Parameter ID="SimSlave" />
</Group>
</Selector>
</Module>
<Module ID="IF4.ST5" Hardware="X20DO9322">
<Selector ID="FunctionModel" Value="Standard">
<Group ID="General">
<Parameter ID="Supervision" Value="off" />
<Parameter ID="ModuleInfo" Value="off" />
<Parameter ID="StatusInfo" Value="on" />
<Parameter ID="DigitalOutputsPacked" Value="off" />
</Group>
<Group ID="Simulation">
<Parameter ID="SimSlave" />
</Group>
</Selector>
</Module>
<Module ID="IF4.ST6" Hardware="X20DO9322">
<Selector ID="FunctionModel" Value="Standard">
<Group ID="General">
<Parameter ID="Supervision" Value="off" />
<Parameter ID="ModuleInfo" Value="off" />
<Parameter ID="StatusInfo" Value="on" />
<Parameter ID="DigitalOutputsPacked" Value="off" />
</Group>
<Group ID="Simulation">
<Parameter ID="SimSlave" />
</Group>
</Selector>
</Module>
<Module ID="IF4.ST7" Hardware="X20DI9371">
<Selector ID="FunctionModel" Value="Standard">
<Group ID="General">
<Parameter ID="Supervision" Value="off" />
<Parameter ID="ModuleInfo" Value="off" />
<Parameter ID="InputFilter" Value="10" />
</Group>
<Group ID="Simulation">
<Parameter ID="SimSlave" />
</Group>
</Selector>
</Module>
<Module ID="IF4.ST8" Hardware="X20AT4222">
<Selector ID="FunctionModel" Value="Standard">
<Group ID="General">
<Parameter ID="Supervision" Value="off" />
<Parameter ID="ModuleInfo" Value="off" />
<Parameter ID="IOCycleCounter" Value="off" />
<Parameter ID="InputFilter" Value="20ms" />
</Group>
<Group ID="Channel01">
<Parameter ID="SensorType01" Value="PT100" />
</Group>
<Group ID="Channel02">
<Parameter ID="SensorType02" Value="PT100" />
</Group>
<Group ID="Channel03">
<Parameter ID="SensorType03" Value="PT100" />
</Group>
<Group ID="Channel04">
<Parameter ID="SensorType04" Value="PT100" />
</Group>
<Group ID="Simulation">
<Parameter ID="SimSlave" />
</Group>
</Selector>
</Module>
<Module ID="IF4.ST9" Hardware="X20AT4222">
<Selector ID="FunctionModel" Value="Standard">
<Group ID="General">
<Parameter ID="Supervision" Value="off" />
<Parameter ID="ModuleInfo" Value="off" />
<Parameter ID="IOCycleCounter" Value="off" />
<Parameter ID="InputFilter" Value="20ms" />
</Group>
<Group ID="Channel01">
<Parameter ID="SensorType01" Value="PT100" />
</Group>
<Group ID="Channel02">
<Parameter ID="SensorType02" Value="PT100" />
</Group>
<Group ID="Channel03">
<Parameter ID="SensorType03" Value="PT100" />
</Group>
<Group ID="Channel04">
<Parameter ID="SensorType04" Value="PT100" />
</Group>
<Group ID="Simulation">
<Parameter ID="SimSlave" />
</Group>
</Selector>
</Module>
</RuntimeConfiguration>

View File

@@ -1,13 +0,0 @@
(********************************************************************
* COPYRIGHT --
********************************************************************
* File: Cpu.per
* Author: Administrator
* Created: December 03, 2009
********************************************************************
* Declaration of permanent variables
********************************************************************)
VAR_CONFIG
END_VAR

View File

@@ -1,23 +0,0 @@
<?xml version="1.0" encoding="utf-8"?>
<?AutomationStudio Version=3.0.80.25?>
<SwConfiguration CpuAddress="SL0" xmlns="http://br-automation.co.at/AS/SwConfiguration">
<TaskClass Name="Cyclic#1" />
<TaskClass Name="Cyclic#2" />
<DataObjects />
<NcDataObjects />
<VcDataObjects />
<Binaries>
<BinaryObject Name="Acp10map" Source="" Memory="UserROM" Language="Binary" />
<BinaryObject Name="Acp10cfg" Source="" Memory="UserROM" Language="Binary" />
<BinaryObject Name="sysconf" Source="" Memory="SystemROM" Language="Binary" />
<BinaryObject Name="iomap" Source="" Memory="UserROM" Language="Binary" />
<BinaryObject Name="ashwd" Source="" Memory="SystemROM" Language="Binary" />
<BinaryObject Name="asfw" Source="" Memory="SystemROM" Language="Binary" />
<BinaryObject Name="arconfig" Source="" Memory="SystemROM" Language="Binary" />
</Binaries>
<Libraries>
<LibraryObject Name="Sys_lib" Source="Libraries.Sys_lib.lby" Memory="UserROM" Language="Binary" />
<LibraryObject Name="Brsystem" Source="Libraries.Brsystem.lby" Memory="UserROM" Language="Binary" />
<LibraryObject Name="Runtime" Source="Libraries.Runtime.lby" Memory="UserROM" Language="Binary" />
</Libraries>
</SwConfiguration>

View File

@@ -1,13 +0,0 @@
(********************************************************************
* COPYRIGHT --
********************************************************************
* File: IoMap.iom
* Author: Administrator
* Created: December 03, 2009
********************************************************************
* IO mapping file
********************************************************************)
VAR_CONFIG
END_VAR

View File

@@ -1,31 +0,0 @@
<?xml version="1.0" encoding="utf-8"?>
<?AutomationStudio Version=3.0.80.25?>
<PLC xmlns="http://br-automation.co.at/AS/PLC">
<Objects>
<Object Type="File" Description="Software configuration">Cpu.sw</Object>
<Object Type="File" Description="Declaration of permanent variables">Cpu.per</Object>
<Object Type="File" Description="IO mapping file">IoMap.iom</Object>
<Object Type="File" Description="PV mapping file">PvMap.vvm</Object>
<Object Type="File" Description="NC mapping file">Acp10map.ncm</Object>
<Object Type="File" Description="ACOPOS parameter configuration">acp10cfg.apc</Object>
<Object Type="File" Description="Runtime configuration file">ArConfig.rtc</Object>
<Object Type="File" Description="NC manager configuration">Acp10cfg.ncc</Object>
<Object Type="File" Description="CPU system configuration">sysconf.br</Object>
<Object Type="File" Description="CPU system configuration">sysconf.syc</Object>
</Objects>
<CpuModules>
<CpuModule LocalVariablesMemory="MemoryPool" GeneratePPCode="false" HasNcOperatingSystem="true" Target="SG4" Address="SL0" ModuleID="AC140" ClassID="8AC141.60-2" GccVersion="V4.1.1" OnlineConfigurationName="TCP_SCR">
<DefaultTargetMemory Tasks="UserROM" Libraries="UserROM" DataObjects="UserROM" />
<DefaultTaskClass Name="None" />
<IO DefaultTaskClass="Automatic" ArConfigDataModule="false" ArConfigDataModulePath="$(AS_CPU_PATH)\AS\CfgData.br" IoMapDataModule="false" IoMapDataModulePath="$(AS_CPU_PATH)\AS\IomData.br" />
<OS Version="3.01.0" Status="A" />
<Transfer DownloadMode="Overload" PromptBeforeProject="false" PromptBeforeTask="false" PackedArConfig="false" PackedIoMap="false" IgnoreTargetOnlyObjects="false" GeneratePviTransferList="true" TransferOnlyRelevantChanges="false" AllowWarmRestart="true" IgnoreBrDependencies="false" />
<Build />
<VC FirmwareVersion="V3.63.8" />
<OPC />
</CpuModule>
</CpuModules>
<Communication>
<OnlineConfiguration Name="TCP_SCR" DeviceType="TCPIP" DeviceParameters="/IF=tcpip /LOPO=11159 /SA=1" ConnectionParameters="/DAIP=192.168.11.239 /CKDA=0 /REPO=11159 /ANSL=1" RoutingPath="" UserName="Administrator" />
</Communication>
</PLC>

View File

@@ -1,13 +0,0 @@
(********************************************************************
* COPYRIGHT --
********************************************************************
* File: PvMap.vvm
* Author: Administrator
* Created: December 03, 2009
********************************************************************
* PV mapping file
********************************************************************)
VAR_CONFIG
END_VAR

View File

@@ -1,75 +0,0 @@
<?xml version="1.0" encoding="utf-8"?>
<?AutomationStudio Version=?>
<AcoposParameterConfiguration>
<Root Name="IF2.ST1" Description="8V1010.50-2">
<Group Name="M1" Description="ScrAcoTab" ModuleDisabled="FALSE">
<Parameter Name="PHASE_MON_IGNORE" ID="80" Value="1" Description="PHASE_MON_IGNORE" />
<Parameter Name="CMD_SIMULATION" ID="110" Value="ncSW_ON" Description="CMD_SIMULATION" />
<Group Name="M1" Disabled="TRUE" Description="8LSA26.E4045D100-0 Rev.C3" StructureEdit="FALSE">
<Group Name="General parameters" Disabled="TRUE">
<Parameter Name="MOTOR_TYPE" ID="30" Value="0x0002" Disabled="TRUE" />
<Parameter Name="MOTOR_COMPATIBILITY" ID="31" Value="0x0203" Disabled="TRUE" />
<Parameter Name="MOTOR_WIND_CONNECT" ID="46" Value="1" Disabled="TRUE" />
<Parameter Name="MOTOR_POLEPAIRS" ID="47" Value="2" Disabled="TRUE" />
</Group>
<Group Name="Brake parameters" Disabled="TRUE">
<Parameter Name="MOTOR_BRAKE_CURR_RATED" ID="42" Value="0" Unit="A" Disabled="TRUE" />
<Parameter Name="MOTOR_BRAKE_TORQ_RATED" ID="43" Value="0" Unit="Nm" Disabled="TRUE" />
<Parameter Name="MOTOR_BRAKE_ON_TIME" ID="44" Value="0" Unit="s" Disabled="TRUE" />
<Parameter Name="MOTOR_BRAKE_OFF_TIME" ID="45" Value="0" Unit="s" Disabled="TRUE" />
</Group>
<Group Name="Thermo sensor parameters" Disabled="TRUE">
<Parameter Name="MOTOR_TEMPSENS_PAR1" ID="64" Value="632" Disabled="TRUE" />
<Parameter Name="MOTOR_TEMPSENS_PAR2" ID="65" Value="2225" Disabled="TRUE" />
<Parameter Name="MOTOR_TEMPSENS_PAR3" ID="66" Value="-30" Disabled="TRUE" />
<Parameter Name="MOTOR_TEMPSENS_PAR4" ID="67" Value="5.7266" Disabled="TRUE" />
<Parameter Name="MOTOR_TEMPSENS_PAR5" ID="68" Value="36.0938" Disabled="TRUE" />
<Parameter Name="MOTOR_TEMPSENS_PAR6" ID="69" Value="62.9375" Disabled="TRUE" />
<Parameter Name="MOTOR_TEMPSENS_PAR7" ID="70" Value="87.25" Disabled="TRUE" />
<Parameter Name="MOTOR_TEMPSENS_PAR8" ID="71" Value="109.6016" Disabled="TRUE" />
<Parameter Name="MOTOR_TEMPSENS_PAR9" ID="72" Value="130.3984" Disabled="TRUE" />
<Parameter Name="MOTOR_TEMPSENS_PAR10" ID="73" Value="150" Disabled="TRUE" />
<Parameter Name="MOTOR_THERMAL_CONST" ID="75" Value="0" Unit="s" Disabled="TRUE" />
</Group>
<Group Name="Motor parameters" Disabled="TRUE">
<Parameter Name="MOTOR_VOLTAGE_RATED" ID="48" Value="400" Unit="V" Disabled="TRUE" />
<Parameter Name="MOTOR_VOLTAGE_CONST" ID="49" Value="58.64" Unit="mV*min" Disabled="TRUE" />
<Parameter Name="MOTOR_SPEED_RATED" ID="50" Value="4500" Unit="1/min" Disabled="TRUE" />
<Parameter Name="MOTOR_SPEED_MAX" ID="51" Value="12000" Unit="1/min" Disabled="TRUE" />
<Parameter Name="MOTOR_TORQ_STALL" ID="52" Value="0.8" Unit="Nm" Disabled="TRUE" />
<Parameter Name="MOTOR_TORQ_RATED" ID="53" Value="0.72" Unit="Nm" Disabled="TRUE" />
<Parameter Name="MOTOR_TORQ_MAX" ID="54" Value="3.2" Unit="Nm" Disabled="TRUE" />
<Parameter Name="MOTOR_TORQ_CONST" ID="55" Value="0.97" Unit="Nm/A" Disabled="TRUE" />
<Parameter Name="MOTOR_CURR_STALL" ID="56" Value="0.824786" Unit="A" Disabled="TRUE" />
<Parameter Name="MOTOR_CURR_RATED" ID="57" Value="0.742307" Unit="A" Disabled="TRUE" />
<Parameter Name="MOTOR_CURR_MAX" ID="58" Value="3.75" Unit="A" Disabled="TRUE" />
<Parameter Name="MOTOR_WIND_CROSS_SECT" ID="59" Value="0.0855" Unit="mm²" Disabled="TRUE" />
<Parameter Name="MOTOR_STATOR_RESISTANCE" ID="60" Value="36.9" Unit="Ohm" Disabled="TRUE" />
<Parameter Name="MOTOR_STATOR_INDUCTANCE" ID="61" Value="0.0669" Unit="Henry" Disabled="TRUE" />
<Parameter Name="MOTOR_INERTIA" ID="62" Value="0.00002" Unit="kgm²" Disabled="TRUE" />
<Parameter Name="MOTOR_COMMUT_OFFSET" ID="63" Value="1e+006" Unit="rad" Disabled="TRUE" />
<Parameter Name="MOTOR_TAU_THERM" ID="849" Value="1800" Unit="s" Disabled="TRUE" />
</Group>
<Group Name="Isolation parameters" Disabled="TRUE">
<Parameter Name="MOTOR_WIND_TEMP_MAX" ID="74" Value="110" Unit="°C" Disabled="TRUE" />
</Group>
</Group>
<Group Name="SS3" Description="8AC120.00" StructureEdit="FALSE">
<Parameter Name="ENCOD2_TYPE" ID="85" Value="ncENDAT" />
<Parameter Name="SCALE_ENCOD2_UNITS" ID="420" Value="10000" Unit="Units" />
<Parameter Name="SCALE_ENCOD2_REV" ID="421" Value="1" />
<Parameter Name="ENCOD2_COUNT_DIR" ID="422" Value="ncSTANDARD" />
<Parameter Name="ENCOD2_S_FILTER_T10" ID="429" Value="0.0" Unit="s" />
<Parameter Name="ENCOD2_S_FILTER_TE" ID="775" Value="0.0" Unit="s" />
</Group>
</Group>
<Group Name="SS3" Description="8AC120.00" StructureEdit="FALSE" ModuleDisabled="FALSE">
<Parameter Name="ENCOD2_TYPE" ID="85" Value="ncENDAT" />
<Parameter Name="SCALE_ENCOD2_UNITS" ID="420" Value="10000" Unit="Units" />
<Parameter Name="SCALE_ENCOD2_REV" ID="421" Value="1" />
<Parameter Name="ENCOD2_COUNT_DIR" ID="422" Value="ncSTANDARD" />
<Parameter Name="ENCOD2_S_FILTER_T10" ID="429" Value="0.0" Unit="s" />
<Parameter Name="ENCOD2_S_FILTER_TE" ID="775" Value="0.0" Unit="s" />
</Group>
</Root>
</AcoposParameterConfiguration>

Binary file not shown.

File diff suppressed because one or more lines are too long

View File

@@ -12,21 +12,6 @@ spi: OBJEKTID=1
{5.3}
klasse: "HC_Moduluebersicht.Class"
name: _PRJ-Moduluebersicht
[1.1]
spi: OBJEKTID=2
spi: OBJEKTID=42
spi: OBJEKTID=43
spi: OBJEKTID=44
spi: OBJEKTID=9
spi: OBJEKTID=10
spi: OBJEKTID=11
spi: OBJEKTID=45
spi: OBJEKTID=22
spi: OBJEKTID=21
{1.2}
klasse: "HC_SPS.Class"
familie: 20
modulname: PLC1
[42.1]
[42.100]
moduladr: 0
@@ -99,35 +84,6 @@ version: 1.0.2.0
{21.1856}
klasse: "X20AT4222"
comparam:
[3.1]
[3.100]
moduladr: 1
modulname: CPU
version: 1.0.1.0
anschlussgrp: "eth2"
anschlussinfo: NUMMER=1, MODULID=0, FLAGS=0
anschlussgrp: "x2x4"
anschlussinfo: NUMMER=1, MODULID=42, FLAGS=1
anschlussinfo: NUMMER=2, MODULID=43, FLAGS=1
anschlussinfo: NUMMER=3, MODULID=44, FLAGS=1
anschlussinfo: NUMMER=4, MODULID=9, FLAGS=1
anschlussinfo: NUMMER=5, MODULID=10, FLAGS=1
anschlussinfo: NUMMER=6, MODULID=11, FLAGS=1
anschlussinfo: NUMMER=7, MODULID=45, FLAGS=1
anschlussinfo: NUMMER=8, MODULID=22, FLAGS=1
anschlussinfo: NUMMER=9, MODULID=21, FLAGS=1
anschlussinfo: NUMMER=10, MODULID=0, FLAGS=0
[3.101]
[3.1840]
comparam_x2x4: SYNCUSAGE=50, IOSIZE=8, RESPTIME=100, BUSLENGTH=1000, STATIONS=64, ASYNCPAYLOAD=80
timingparam_x2x4: CYCLETIME=2000, PRESCALE=1
[3.1632]
comparam_eth2: IP=192.168.11.242, MASK=255.255.255.0, GATEWAY=192.168.11.254, BROADCAST=255.255.255.255, FORCE
inaparam_eth2: PORTNO=11159, FORCE
cfgparam_eth2: SOCKETCNT=16, DESCRCNT=16, MEMBUFCNT=453, ARPTBLENTRCNT=16, PAGECNT=16, ROUTINGENTRCNT=0, FBSERVERPORT=11159, FBTCPPRI=182, PNADAEMONPRI=184, LIBPRI=183, BROADCASTCNT=5
[3.1824]
{3.108}
klasse: "X20CP0292"
[2.1]
[2.100]
moduladr: 0
@@ -183,3 +139,62 @@ version: 1.0.2.0
{11.1856}
klasse: "X20DO9322"
comparam:
[23.1]
[23.100]
moduladr: 0
verbunden: 3
station: 10
busart: 6
version: 1.0.1.0
[23.101]
[23.1824]
{23.1856}
klasse: "X20DI9371"
comparam:
[1.1]
spi: OBJEKTID=2
spi: OBJEKTID=42
spi: OBJEKTID=43
spi: OBJEKTID=44
spi: OBJEKTID=9
spi: OBJEKTID=10
spi: OBJEKTID=11
spi: OBJEKTID=45
spi: OBJEKTID=22
spi: OBJEKTID=21
spi: OBJEKTID=23
{1.2}
klasse: "HC_SPS.Class"
familie: 20
modulname: PLC1
[3.1]
[3.100]
moduladr: 1
modulname: CPU
version: 1.0.1.0
prescaler: 5
anschlussgrp: "eth2"
anschlussinfo: NUMMER=1, MODULID=0, FLAGS=0
anschlussgrp: "x2x4"
anschlussinfo: NUMMER=1, MODULID=42, FLAGS=1
anschlussinfo: NUMMER=2, MODULID=43, FLAGS=1
anschlussinfo: NUMMER=3, MODULID=44, FLAGS=1
anschlussinfo: NUMMER=4, MODULID=9, FLAGS=1
anschlussinfo: NUMMER=5, MODULID=10, FLAGS=1
anschlussinfo: NUMMER=6, MODULID=11, FLAGS=1
anschlussinfo: NUMMER=7, MODULID=45, FLAGS=1
anschlussinfo: NUMMER=8, MODULID=22, FLAGS=1
anschlussinfo: NUMMER=9, MODULID=21, FLAGS=1
anschlussinfo: NUMMER=10, MODULID=23, FLAGS=1
anschlussinfo: NUMMER=11, MODULID=0, FLAGS=0
[3.101]
[3.1840]
comparam_x2x4: SYNCUSAGE=50, IOSIZE=8, RESPTIME=100, BUSLENGTH=1000, STATIONS=64, ASYNCPAYLOAD=80
timingparam_x2x4: CYCLETIME=2000, PRESCALE=1
[3.1632]
comparam_eth2: IP=192.168.11.242, MASK=255.255.255.0, GATEWAY=192.168.11.254, BROADCAST=255.255.255.255, FORCE
inaparam_eth2: PORTNO=11159, FORCE
cfgparam_eth2: SOCKETCNT=16, DESCRCNT=16, MEMBUFCNT=453, ARPTBLENTRCNT=16, PAGECNT=16, ROUTINGENTRCNT=0, FBSERVERPORT=11159, FBTCPPRI=182, PNADAEMONPRI=184, LIBPRI=183, BROADCASTCNT=5
[3.1824]
{3.108}
klasse: "X20CP0292"

View File

@@ -1,6 +1,6 @@
<?xml version="1.0" encoding="utf-8"?>
<?AutomationStudio Version=3.0.80.25?>
<RuntimeConfiguration Version="2.30.22">
<?AutomationStudio Version=?>
<RuntimeConfiguration Version="2.31.2">
<Module ID="IF2" Hardware="X20CP0292">
<Group ID="Device">
<Parameter ID="ActivateDevice" Value="1" />
@@ -21,7 +21,7 @@
<Module ID="IF4.ST5" Hardware="X20DO9322">
<Selector ID="FunctionModel" Value="Standard">
<Group ID="General">
<Parameter ID="Supervision" Value="on" />
<Parameter ID="Supervision" Value="off" />
<Parameter ID="ModuleInfo" Value="off" />
<Parameter ID="StatusInfo" Value="on" />
<Parameter ID="DigitalOutputsPacked" Value="off" />
@@ -41,7 +41,7 @@
<Module ID="IF4.ST1" Hardware="X20DI9371">
<Selector ID="FunctionModel" Value="Standard">
<Group ID="General">
<Parameter ID="Supervision" Value="on" />
<Parameter ID="Supervision" Value="off" />
<Parameter ID="ModuleInfo" Value="off" />
<Parameter ID="InputFilter" Value="10" />
</Group>
@@ -50,7 +50,7 @@
<Module ID="IF4.ST2" Hardware="X20DI9371">
<Selector ID="FunctionModel" Value="Standard">
<Group ID="General">
<Parameter ID="Supervision" Value="on" />
<Parameter ID="Supervision" Value="off" />
<Parameter ID="ModuleInfo" Value="off" />
<Parameter ID="InputFilter" Value="10" />
</Group>
@@ -59,7 +59,7 @@
<Module ID="IF4.ST3" Hardware="X20DI9371">
<Selector ID="FunctionModel" Value="Standard">
<Group ID="General">
<Parameter ID="Supervision" Value="on" />
<Parameter ID="Supervision" Value="off" />
<Parameter ID="ModuleInfo" Value="off" />
<Parameter ID="InputFilter" Value="10" />
</Group>
@@ -68,7 +68,7 @@
<Module ID="IF4.ST7" Hardware="X20DI9371">
<Selector ID="FunctionModel" Value="Standard">
<Group ID="General">
<Parameter ID="Supervision" Value="on" />
<Parameter ID="Supervision" Value="off" />
<Parameter ID="ModuleInfo" Value="off" />
<Parameter ID="InputFilter" Value="10" />
</Group>
@@ -77,7 +77,7 @@
<Module ID="IF4.ST4" Hardware="X20DO9322">
<Selector ID="FunctionModel" Value="Standard">
<Group ID="General">
<Parameter ID="Supervision" Value="on" />
<Parameter ID="Supervision" Value="off" />
<Parameter ID="ModuleInfo" Value="off" />
<Parameter ID="StatusInfo" Value="on" />
<Parameter ID="DigitalOutputsPacked" Value="off" />
@@ -87,7 +87,7 @@
<Module ID="IF4.ST8" Hardware="X20AT4222">
<Selector ID="FunctionModel" Value="Standard">
<Group ID="General">
<Parameter ID="Supervision" Value="on" />
<Parameter ID="Supervision" Value="off" />
<Parameter ID="ModuleInfo" Value="off" />
<Parameter ID="IOCycleCounter" Value="off" />
<Parameter ID="InputFilter" Value="20ms" />
@@ -129,4 +129,23 @@
</Selector>
</Module>
<Module ID="IF4" Hardware="X20CP0292 (X2x)" />
<Module ID="IF4.ST10" Hardware="X20DI9371">
<Selector ID="FunctionModel" Value="Standard">
<Group ID="General">
<Parameter ID="Supervision" Value="off" />
<Parameter ID="ModuleInfo" Value="off" />
<Parameter ID="InputFilter" Value="10" />
</Group>
</Selector>
</Module>
<Module ID="IF4.ST6" Hardware="X20DO9322">
<Selector ID="FunctionModel" Value="Standard">
<Group ID="General">
<Parameter ID="Supervision" Value="off" />
<Parameter ID="ModuleInfo" Value="off" />
<Parameter ID="StatusInfo" Value="on" />
<Parameter ID="DigitalOutputsPacked" Value="off" />
</Group>
</Selector>
</Module>
</RuntimeConfiguration>

View File

@@ -1,5 +1,5 @@
<?xml version="1.0" encoding="utf-8"?>
<?AutomationStudio Version=3.0.80.25?>
<?AutomationStudio Version=3.0.80.31 SP01?>
<SwConfiguration CpuAddress="" xmlns="http://br-automation.co.at/AS/SwConfiguration">
<TaskClass Name="Cyclic#1">
<Task Name="c_munin" Source="Communication.c_munin.prg" Memory="UserROM" Language="ANSIC" Debugging="true" />
@@ -24,12 +24,14 @@
<Task Name="m_gang" Source="Wohnung.m_gang.prg" Memory="UserROM" Language="IEC" AnsiToAscii="true" Version="1.00.0" />
<Task Name="m_kz" Source="Wohnung.m_kz.prg" Memory="UserROM" Language="IEC" AnsiToAscii="true" Version="1.00.0" />
<Task Name="m_kih" Source="Wohnung.m_kih.prg" Memory="UserROM" Language="IEC" AnsiToAscii="true" Version="1.00.0" />
<Task Name="m_kti" Source="Wohnung.m_kti.prg" Memory="UserROM" Language="IEC" />
<Task Name="m_speis" Source="Wohnung.m_speis.prg" Memory="UserROM" Language="IEC" AnsiToAscii="true" Version="1.00.0" />
<Task Name="m_wz" Source="Wohnung.m_wz.prg" Memory="UserROM" Language="IEC" AnsiToAscii="true" Version="1.00.0" />
<Task Name="m_au" Source="Wohnung.m_au.prg" Memory="UserROM" Language="IEC" AnsiToAscii="true" Version="1.00.0" />
<Task Name="m_bad1" Source="Wohnung.m_bad1.prg" Memory="UserROM" Language="IEC" AnsiToAscii="true" Version="1.00.0" />
<Task Name="m_az" Source="Wohnung.m_az.prg" Memory="UserROM" Language="IEC" AnsiToAscii="true" Version="1.00.0" />
<Task Name="m_gz" Source="Wohnung.m_gz.prg" Memory="UserROM" Language="IEC" AnsiToAscii="true" Version="1.00.0" />
<Task Name="m_OG" Source="Wohnung.m_OG.prg" Memory="UserROM" Language="IEC" />
<Task Name="th1" Source="Treppenhaus.th1.prg" Memory="UserROM" Language="IEC" AnsiToAscii="true" Version="1.00.0" />
<Task Name="th2" Source="Treppenhaus.th2.prg" Memory="UserROM" Language="IEC" AnsiToAscii="true" Version="1.00.0" />
<Task Name="w_kuch1" Source="Apartment.w_kuch1.prg" Memory="UserROM" Language="IEC" AnsiToAscii="true" Version="1.00.0" />
@@ -38,7 +40,6 @@
<Task Name="w_klo" Source="Apartment.w_klo.prg" Memory="UserROM" Language="IEC" AnsiToAscii="true" Version="1.00.0" />
<Task Name="w_wz2" Source="Apartment.w_wz2.prg" Memory="UserROM" Language="IEC" AnsiToAscii="true" Version="1.00.0" />
<Task Name="heat" Source="Temperature.heat.prg" Memory="UserROM" Language="IEC" />
<Task Name="m_kti" Source="Wohnung.m_kti.prg" Memory="UserROM" Language="IEC" />
</TaskClass>
<TaskClass Name="Cyclic#4" />
<DataObjects />
@@ -46,10 +47,10 @@
<VcDataObjects />
<Binaries>
<BinaryObject Name="gcloader" Source="" Memory="UserROM" Language="Binary" />
<BinaryObject Name="sysconf" Source="" Memory="SystemROM" Language="Binary" />
<BinaryObject Name="iomap" Source="" Memory="UserROM" Language="Binary" />
<BinaryObject Name="asfw" Source="" Memory="UserROM" Language="Binary" />
<BinaryObject Name="arconfig" Source="" Memory="UserROM" Language="Binary" />
<BinaryObject Name="asfw" Source="" Memory="UserROM" Language="Binary" />
<BinaryObject Name="iomap" Source="" Memory="UserROM" Language="Binary" />
<BinaryObject Name="sysconf" Source="" Memory="SystemROM" Language="Binary" />
</Binaries>
<Libraries>
<LibraryObject Name="SYS_LIB" Source="Libraries.SYS_LIB.lby" Memory="UserROM" Language="Binary" />

View File

@@ -106,4 +106,17 @@ VAR_CONFIG
A9.iTemp[1] AT %IW.IF4.ST9.Temperature02;
A9.iTemp[2] AT %IW.IF4.ST9.Temperature03;
A9.iTemp[3] AT %IW.IF4.ST9.Temperature04;
A10.bModuleOk AT %IX.IF4.ST10.ModuleOk;
A10.DIn[0] AT %IX.IF4.ST10.DigitalInput01;
A10.DIn[1] AT %IX.IF4.ST10.DigitalInput02;
A10.DIn[2] AT %IX.IF4.ST10.DigitalInput03;
A10.DIn[3] AT %IX.IF4.ST10.DigitalInput04;
A10.DIn[4] AT %IX.IF4.ST10.DigitalInput05;
A10.DIn[5] AT %IX.IF4.ST10.DigitalInput06;
A10.DIn[6] AT %IX.IF4.ST10.DigitalInput07;
A10.DIn[7] AT %IX.IF4.ST10.DigitalInput08;
A10.DIn[8] AT %IX.IF4.ST10.DigitalInput09;
A10.DIn[9] AT %IX.IF4.ST10.DigitalInput10;
A10.DIn[10] AT %IX.IF4.ST10.DigitalInput11;
A10.DIn[11] AT %IX.IF4.ST10.DigitalInput12;
END_VAR

View File

@@ -1,5 +1,5 @@
<?xml version="1.0" encoding="utf-8"?>
<?AutomationStudio Version=3.0.80.25?>
<?AutomationStudio Version=3.0.80.31 SP01?>
<PLC xmlns="http://br-automation.co.at/AS/PLC">
<Objects>
<Object Type="File" Description="Software configuration">Cpu.sw</Object>
@@ -13,16 +13,18 @@
<Object Type="File">sysconf.br</Object>
</Objects>
<CpuModules>
<CpuModule LocalVariablesMemory="MemoryPool" GeneratePPCode="false" HasNcOperatingSystem="true" Target="SGC" Address="SL1" ModuleID="CP0292" ClassID="X20CP0292" GccVersion="V2.95.3">
<CpuModule LocalVariablesMemory="MemoryPool" GeneratePPCode="false" HasNcOperatingSystem="true" Target="SGC" Address="SL1" ModuleID="CP0292" ClassID="X20CP0292" GccVersion="V2.95.3" OnlineConfigurationName="TCPIP_HOME">
<DefaultTargetMemory Tasks="UserROM" Libraries="UserROM" DataObjects="UserROM" />
<DefaultTaskClass Name="Cyclic4" />
<IO DefaultTaskClass="Automatic" ArConfigDataModule="false" ArConfigDataModulePath="$(AS_CPU_PATH)\AS\CfgData.br" IoMapDataModule="false" IoMapDataModulePath="$(AS_CPU_PATH)\AS\IomData.br" />
<OS Version="2.30.0" Status="V" />
<OS Version="2.31.0" Status="B" />
<Transfer DownloadMode="Overload" PromptBeforeProject="false" PromptBeforeTask="false" PackedArConfig="false" PackedIoMap="false" IgnoreTargetOnlyObjects="false" GeneratePviTransferList="true" TransferOnlyRelevantChanges="false" AllowWarmRestart="true" IgnoreBrDependencies="false" />
<Build />
<VC FirmwareVersion="V3.63.8" />
<OPC />
</CpuModule>
</CpuModules>
<Communication />
<Communication>
<OnlineConfiguration Name="TCPIP_HOME" DeviceType="TCPIP" DeviceParameters="/IF=tcpip /LOPO=11159 /SA=11" ConnectionParameters="/DAIP=192.168.11.242 /CKDA=0 /REPO=11159 /ANSL=1" RoutingPath="" UserName="Administrator" />
</Communication>
</PLC>

Binary file not shown.

Binary file not shown.

Binary file not shown.

View File

@@ -1,10 +1,9 @@
<?xml version="1.0" encoding="utf-8"?>
<?AutomationStudio Version=3.0.80.25?>
<?AutomationStudio Version=3.0.80.31 SP01?>
<Physical xmlns="http://br-automation.co.at/AS/Physical">
<Configurations>
<Configuration Name="HomeSPS" Description="" />
<Configuration Name="Simu" Description="" />
<Configuration Name="Acopos" Description="" />
<Configuration Name="PP45" Description="" />
</Configurations>
</Physical>

File diff suppressed because it is too large Load Diff

Some files were not shown because too many files have changed in this diff Show More