"""Sunsynk hybrid inverter sensor definitions."""
|
|
|
|
CELSIUS = "C"
|
|
KWH = "kWh"
|
|
AMPS = "A"
|
|
VOLT = "V"
|
|
WATT = "W"
|
|
|
|
_SENSORS = []
|
|
|
|
##########
|
|
# Battery
|
|
##########
|
|
|
|
#################
|
|
# Inverter Power
|
|
#################
|
|
|
|
#############
|
|
# Grid Power
|
|
#############
|
|
#_SENSORS += (
|
|
# (169, "Grid power", WATT, -1), # L1(167) + L2(168)
|
|
# (167, "Grid LD power", WATT, -1), # L1 seems to be LD
|
|
# (168, "Grid L2 power", WATT, -1),
|
|
# (150, "Grid voltage", VOLT, 0.1),
|
|
# (598, "Grid voltage L1", VOLT, 0.1),
|
|
# (599, "Grid voltage L2", VOLT, 0.1),
|
|
# (600, "Grid voltage L3", VOLT, 0.1),
|
|
# ((160, 161), "Grid current", AMPS, (0.01, 0.01)),
|
|
# (172, "Grid CT power", WATT, -1),
|
|
#)
|
|
|
|
#############
|
|
# Load Power
|
|
#############
|
|
|
|
################
|
|
# Solar Power 1
|
|
################
|
|
|
|
################
|
|
# Solar Power 2
|
|
################
|
|
|
|
###################
|
|
# Power on Outputs
|
|
###################
|
|
_SENSORS += (
|
|
(609, "Grid frequency", "Hz", 0.01),
|
|
(640, "UPS Load Power L1", "W", 1),
|
|
(641, "UPS Load Power L2", "W", 1),
|
|
(642, "UPS Load Power L3", "W", 1),
|
|
(643, "UPS Load Power Total", "W", 1),
|
|
(644, "Load Voltage L1", "V", 1),
|
|
(645, "Load Voltage L2", "V", 1),
|
|
(646, "Load Voltage L3", "V", 1),
|
|
(650, "Load Power L1", "W", 1),
|
|
(651, "Load Power L2", "W", 1),
|
|
(652, "Load Power L3", "W", 1),
|
|
(653, "Load Power Total", "W", 1),
|
|
(654, "Load Power Appearent", "W", 1),
|
|
(655, "Load Frequency", "Hz", 1),
|
|
(661, "Gen Port Voltage L1", "V", 1),
|
|
(662, "Gen Port Voltage L1", "V", 1),
|
|
(663, "Gen Port Voltage L1", "V", 1),
|
|
(664, "Gen Port Power L1", "W", 1),
|
|
(665, "Gen Port Power L2", "W", 1),
|
|
(666, "Gen Port Power L3", "W", 1),
|
|
(667, "Gen Port Power Total", "W", 1),
|
|
(133, "Gen Port Usage ", "", 1),
|
|
(134, "Smart Load Off Bat Voltage ", "V", 1),
|
|
(135, "Smart Load Off Bat SOC ", "V", 1),
|
|
(136, "Smart Load On Bat Voltage ", "V", 1),
|
|
(137, "Smart Load On Bat SOC ", "V", 1),
|
|
(552, "AC Relay State ", "", 1),
|
|
(604, "InnerGrid Power L1 ", "", 1),
|
|
(605, "InnerGrid Power L2 ", "", 1),
|
|
(606, "InnerGrid Power L3 ", "", 1),
|
|
(607, "Act Power Side To Side ", "", 1),
|
|
(616, "Out-Of-Grid Power L1 ", "W", 1),
|
|
(617, "Out-Of-Grid Power L2 ", "W", 1),
|
|
(618, "Out-Of-Grid Power L3 ", "W", 1),
|
|
(619, "Out-Of-Grid Power Total ", "W", 1),
|
|
(622, "Grid-Side Power L1 ", "W", 1),
|
|
(623, "Grid-Side Power L2 ", "W", 1),
|
|
(624, "Grid-Side Power L3 ", "W", 1),
|
|
(625, "Grid-Side Power Total ", "W", 1),
|
|
(633, "Inv Output Power L1 ", "W", 1),
|
|
(634, "Inv Output Power L2 ", "W", 1),
|
|
(635, "Inv Output Power L3 ", "W", 1),
|
|
(636, "Inv Output Power Total ", "W", 1),
|
|
)
|
|
|
|
###################
|
|
# Energy
|
|
###################
|
|
|
|
##########
|
|
# General
|
|
##########
|
|
|
|
###########
|
|
# Settings
|
|
###########
|